Ram FS, Wright J, Brocklebank D, White JE.
Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.
BMJ 2001 Oct 20; 323:(7318):901-5
http://www.bmj.com/cgi/content/full/323/7318/901?view=long&pmid=11668134


Abstract:

OBJECTIVES: To determine the clinical effectiveness of pressurised metered dose inhalers compared with other hand held inhaler devices for delivering short acting beta(2) agonists in stable asthma. DESIGN: Systematic review of randomised controlled trials. DATA SOURCES: Cochrane Airways Group specialised trials database (which includes hand searching of 20 relevant journals), Medline, Embase, Cochrane controlled clinical trials register, pharmaceutical companies, and bibliographies of included trials. TRIALS: All trials in children or adults with stable asthma that compared the pressurised metered dose inhaler (with or without a spacer device) against any other hand held inhaler device containing the same beta(2) agonist. Results: 84 randomised controlled trials were included. No differences were found between the pressurised metered dose inhaler and any other hand held inhaler device for lung function, blood pressure, symptoms, bronchial hyperreactivity, systemic bioavailability, inhaled steroid requirement, serum potassium concentration, and use of additional relief bronchodilators. In adults, pulse rate was lower in those using the pressurised metered dose inhaler compared with those using Turbohaler (standardised mean difference 0.44, 95% confidence interval 0.05 to 0.84); patients preferred the pressurised metered dose inhaler to the Rotahaler (relative risk 0.53, 95% confidence interval 0.36 to 0.78); hydrofluoroalkane pressurised metered dose inhalers reduced the requirement for rescue short course oral steroids (relative risk 0.67, 0.49 to 0.91). CONCLUSIONS: No evidence was found to show that alternative inhaler devices are more effective than standard pressurised metered dose inhalers for delivering acting beta(2 )agonist bronchodilators in asthma. Pressurised metered dose inhalers remain the most cost effective delivery devices.

Keywords:
* Adrenergic beta-Agonists/administration & dosage* * Adrenergic beta-Agonists/therapeutic use * Adult * Asthma/drug therapy* * Asthma/physiopathology * Bronchodilator Agents/administration & dosage* * Bronchodilator Agents/therapeutic use * Child * Drug Administration Schedule * Humans * Nebulizers and Vaporizers* * Patient Satisfaction * Randomized Controlled Trials as Topic * Treatment Outcome

 

  Healthy Skepticism on RSS   Healthy Skepticism on Facebook   Healthy Skepticism on Twitter

Please
Click to Register

(read more)

then
Click to Log in
for free access to more features of this website.

Forgot your username or password?

You are invited to
apply for membership
of Healthy Skepticism,
if you support our aims.

Pay a subscription

Support our work with a donation

Buy Healthy Skepticism T Shirts


If there is something you don't like, please tell us. If you like our work, please tell others.

Email a Friend